Optimierung des Debondingverfahrens in der Bracketadhäsivtechnik
Optimierung des Debondingverfahrens in der Bracketadhäsivtechnik
dc.contributor.advisor | Jäger, Andreas | |
dc.contributor.author | Sanad, Mohammed | |
dc.date.accessioned | 2020-07-10T14:35:30Z | |
dc.date.available | 2020-07-10T14:35:30Z | |
dc.date.issued | 10.07.2020 | |
dc.identifier.uri | https://hdl.handle.net/20.500.11811/8448 | |
dc.description.abstract | Einleitung: Das Endziel des Bracket-Debonding ist, eine dem naturbelassenen Schmelz ähnliche Oberfläche zu hinterlassen. Verschiedene Faktoren wie z. B. verwendetes Adhäsiv, Debondingverfahren oder Polierinstrumente haben einen Einfluss auf den Schmelzverlust beim Debonding. Das Ziel der vorliegenden In-vitro-Untersuchung war die Entwicklung von adhäsiv-spezifischen Debondingprotokollen. Material und Methodik: 144 Frontzahnbrackets (Discovery Zahn 11, Fa. Dentaurum, Deutschland) wurden mit sechs verschiedenen Adhäsivsystemen auf 48 extrahierten Inzisivi-Rinderzähnen (Zahn 11, Fa. Rocholl, Deutschland) befestigt. Nach dem Aufbringen der Brackets wurden diese mit einer Bracketentfernungszange oder einem Cutter entfernt. Die verbliebenen Kunststoffe wurden mittels lichtmikroskopischer Aufnahmen mithilfe des ARI (Adhesive Remnant Index) evaluiert. In einer zweiten Phase wurden die verbliebene Kunststoffe mit einem Karbidfinierer (30.000 ump bzw. 100.000 upm), Finierdiamant oder Metallfinierer entfernt. Nach dem Kleberentfernen wurden die Oberflächen in Phase drei mit einer Nylonbürste oder einem Universalpolierer poliert. Die Oberflächenrauheiten wurden mittels eines Profilometers evaluiert. Ergebnisse: Die Bracketentfernungszange hatte bei Opal® bond MV, ConTec LC und ConTec SE die meisten Adhäsivreste, gekennzeichnet durch erhöhte ARI-Werte. In Phase 2 wurde mit dem Hartmetallfinierer der höchste Rauheitswert bei allen Adhäsivmaterialien, außer Contec SE, erzeugt. Bei Opal® bond MV, Transbond™XT und ConTec SE waren die Rauheits-Werte mit dem Carbidfinierer bei 30.000 r/min, bei Opal®bond mit dem Carbidfinierer bei 100.000 r/min und bei Transbond™Plus und ConTec LC mit dem Finierdiamanten am niedrigsten. Nach der Politur, d. h. bei Abschluss von Phase 3, waren die Rauheitswerte mit dem Universalpolierer höher als diejenigen der Nylonbürste. | de |
dc.description.abstract | Introduction: The goal of bracket debonding is to leave a surface similar to the natural enamel. Various factors such as B. Adhesive used, debonding process or polishing instruments have an influence on the melt loss during debonding. The aim of the present in vitro investigation was the development of adhesive-specific debonding protocols.
Material and method: 144 anterior tooth brackets (Discovery tooth 11, Dentaurum, Germany) were attached to 48 extracted incisor bovine teeth (tooth 11, Rocholl, Germany) using six different adhesive systems. After the brackets had been applied, they were removed using a bracket removal pliers or a cutter. The remaining plastics were evaluated using light microscopic images using the ARI (Adhesive Remnant Index). In a second phase, the remaining plastics were removed with a carbide finisher (30,000 rpm or 100,000 rpm), finishing diamond or metal finisher. After the adhesive was removed, the surfaces were polished in phase three with a nylon brush or a universal polisher. The surface roughness was evaluated using a profilometer. Results: The bracket removal pliers had the most adhesive residues with Opal® bond MV, ConTec LC and ConTec SE, characterized by increased ARI values. In phase 2, the highest roughness value for all adhesive materials, except Contec SE, was generated with the hard metal finisher. With Opal® bond MV, Transbond ™ XT and ConTec SE, the roughness values with the carbide finisher were at 30,000 r / min, with Opal®bond with the carbide finisher at 100,000 r / min and with Transbond ™ Plus and ConTec LC with the finishing diamond lowest. After polishing, d. H. when phase 3 was completed, the roughness values with the universal polisher were higher than those with the nylon brush. | en |
dc.language.iso | deu | |
dc.rights | In Copyright | |
dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | |
dc.subject | Debonding-Verfahren | |
dc.subject | Bracket-Entfernung | |
dc.subject | Debonding | |
dc.subject | Restkleber | |
dc.subject | lichtmikroskopischer | |
dc.subject | Adhesive Remnant Index | |
dc.subject | Profilometer | |
dc.subject | Rasterelektronenmikroskop | |
dc.subject | Bonding process | |
dc.subject | bracket removal | |
dc.subject | residual adhesive | |
dc.subject | light microscopic | |
dc.subject | scanning electron microscope | |
dc.subject.ddc | 610 Medizin, Gesundheit | |
dc.title | Optimierung des Debondingverfahrens in der Bracketadhäsivtechnik | |
dc.type | Dissertation oder Habilitation | |
dc.publisher.name | Universitäts- und Landesbibliothek Bonn | |
dc.publisher.location | Bonn | |
dc.rights.accessRights | openAccess | |
dc.identifier.urn | https://nbn-resolving.org/urn:nbn:de:hbz:5-58236 | |
ulbbn.pubtype | Erstveröffentlichung | |
ulbbn.birthname | Sanad | |
ulbbnediss.affiliation.name | Rheinische Friedrich-Wilhelms-Universität Bonn | |
ulbbnediss.affiliation.location | Bonn | |
ulbbnediss.thesis.level | Dissertation | |
ulbbnediss.dissID | 5823 | |
ulbbnediss.date.accepted | 16.03.2020 | |
ulbbnediss.institute | Medizinische Fakultät / Kliniken : Poliklinik für Kieferorthopädie | |
ulbbnediss.fakultaet | Medizinische Fakultät | |
dc.contributor.coReferee | Stark, Helmut |
Dateien zu dieser Ressource
Das Dokument erscheint in:
-
E-Dissertationen (1577)