Zur Kurzanzeige

Comparative Analysis of Shear Bond Strength in Orthodontic Brackets Between Milled and 3D-Printed Definitive CAD/CAM Restorations

dc.contributor.authorAldosari, Mohammad A.
dc.contributor.authorAnany, Noha M.
dc.contributor.authorAlaqeely, Razan
dc.contributor.authorAlsenaidi, Jawaher
dc.contributor.authorSufyan, Aref
dc.contributor.authorTalaat, Sameh
dc.contributor.authorBourauel, Christoph
dc.contributor.authorElshazly, Tarek M.
dc.contributor.authorAlhotan, Abdulaziz
dc.date.accessioned2025-08-08T11:17:54Z
dc.date.available2025-08-08T11:17:54Z
dc.date.issued18.10.2024
dc.identifier.urihttps://hdl.handle.net/20.500.11811/13334
dc.description.abstractObjective: The objective of this study was to evaluate the effect of different surface treatment methods on the shear bond strength (SBS) of metal brackets bonded to two types of CAD/CAM composite restorations: milled and 3D-printed. Materials and Methods: A total of 160 flat-shaped specimens (10 × 10 × 2 mm3) were prepared from four different CAD/CAM composites; two milled (Lava Ultimate™ [LU] and Grandio™ [GR]) and two 3D-printed (Crowntec™ [CT] and C&B Permanent™ [CB]). These specimens underwent thermocycling (5000 cycles at 5–55 °C), then were categorized based on the surface treatment into four groups (n = 10): Group C (control, no surface treatment), Group HF (treated with 9.6% hydrofluoric acid), Group DB (mechanical roughening by a diamond bur), and Group SB (sandblasting using aluminum oxide). Metal brackets were bonded using Transbond XT Primer and universal adhesive, stored in artificial saliva for 24 h, then thermo-cycled again. Shear bond strength (SBS) was tested using a universal testing machine until bracket debonding occurred. The adhesive remnant index (ARI) was assessed using a stereomicroscope to quantify the residual adhesive following debonding. Result: Regarding material, GR and LU restorations had significantly higher SBS values compared to CT and CB, ranging from 13.90 MPa to 20.35 MPa. Regarding surface treatment, SB and HF groups showed significantly higher SBS values. The ARI scores showed different adhesive modes of failure, with higher instances of scores 0 and 1, which indicate no or minimal adhesive remaining. Conclusions: Both milled and 3D-printed materials had adequate SBS for clinical use, with milled materials showing superior results. Surface treatments like sandblasting and HF significantly improved bond strength, with adhesive failure being common.en
dc.format.extent12
dc.language.isoeng
dc.rightsNamensnennung 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectdentistry
dc.subjectorthodontics
dc.subjectbiomechanics
dc.subjectcementation
dc.subjectbrackets
dc.subjectthermocycling
dc.subjectaging
dc.subject.ddc600 Technik
dc.subject.ddc610 Medizin, Gesundheit
dc.titleComparative Analysis of Shear Bond Strength in Orthodontic Brackets Between Milled and 3D-Printed Definitive CAD/CAM Restorations
dc.typeWissenschaftlicher Artikel
dc.publisher.nameMDPI
dc.publisher.locationBasel
dc.rights.accessRightsopenAccess
dcterms.bibliographicCitation.volume2024, vol. 14
dcterms.bibliographicCitation.issueiss. 20, 9530
dcterms.bibliographicCitation.pagestart1
dcterms.bibliographicCitation.pageend12
dc.relation.doihttps://doi.org/10.3390/app14209530
dcterms.bibliographicCitation.journaltitleApplied Sciences
ulbbn.pubtypeZweitveröffentlichung
dc.versionpublishedVersion
ulbbn.sponsorship.oaUnifundOA-Förderung Universität Bonn


Dateien zu dieser Ressource

Thumbnail

Das Dokument erscheint in:

Zur Kurzanzeige

Die folgenden Nutzungsbestimmungen sind mit dieser Ressource verbunden:

Namensnennung 4.0 International