Zur Kurzanzeige

Reliability of Retinal Layer Annotation with a Novel, High-Resolution Optical Coherence Tomography Device
A Comparative Study

dc.contributor.authorvon der Emde, Leon
dc.contributor.authorSaßmannshausen, Marlene
dc.contributor.authorMorelle, Olivier
dc.contributor.authorRennen, Geena
dc.contributor.authorHolz, Frank
dc.contributor.authorWintergerst, Maximilian
dc.contributor.authorAch, Thomas
dc.date.accessioned2023-04-28T11:29:10Z
dc.date.available2023-04-28T11:29:10Z
dc.date.issued31.03.2023
dc.identifier.urihttps://hdl.handle.net/20.500.11811/10799
dc.description.abstractOptical coherence tomography (OCT) enables in vivo diagnostics of individual retinal layers in the living human eye. However, improved imaging resolution could aid diagnosis and monitoring of retinal diseases and identify potential new imaging biomarkers. The investigational high-resolution OCT platform (High-Res OCT; 853 nm central wavelength, 3 μm axial-resolution) has an improved axial resolution by shifting the central wavelength and increasing the light source band- width compared to a conventional OCT device (880 nm central wavelength, 7 μm axial-resolution). To assess the possible benefit of a higher resolution, we compared the retest reliability of retinal layer annotation from conventional and High-Res OCT, evaluated the use of High-Res OCT in pa- tients with age-related macular degeneration (AMD), and assessed differences of both devices on subjective image quality. Thirty eyes of 30 patients with early/intermediate AMD (iAMD; mean age 75 ± 8 years) and 30 eyes of 30 age-similar subjects without macular changes (62 ± 17 years) underwent identical OCT imaging on both devices. Inter- and intra-reader reliability were analyzed for manual retinal layer annotation using EyeLab. Central OCT B-scans were graded for image quality by two graders and a mean-opinion-score (MOS) was formed and evaluated. Inter- and intra-reader reliability were higher for High-Res OCT (greatest benefit for inter-reader reliability: ganglion cell layer; for intra-reader reliability: retinal nerve fiber layer). High-Res OCT was signifi- cantly associated with an improved MOS (MOS 9/8, Z-value = 5.4, p < 0.01) mainly due to improved subjective resolution (9/7, Z-Value 6.2, p < 0.01). The retinal pigment epithelium drusen complex showed a trend towards improved retest reliability in High-Res OCT in iAMD eyes but without statistical significance. Improved axial resolution of the High-Res OCT benefits retest reliability of retinal layer annotation and improves perceived image quality and resolution. Automated image analysis algorithms could also benefit from the increased image resolution.de
dc.format.extent12
dc.language.isoeng
dc.rightsNamensnennung 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectOCT
dc.subjectspectral-domain
dc.subjectage-related macular degeneration
dc.subjectaxial resolution
dc.subjecthigh resolution
dc.subjectsegmentation
dc.subjectannotation
dc.subject.ddc610 Medizin, Gesundheit
dc.titleReliability of Retinal Layer Annotation with a Novel, High-Resolution Optical Coherence Tomography Device
dc.title.alternativeA Comparative Study
dc.typeWissenschaftlicher Artikel
dc.publisher.nameMDPI
dc.rights.accessRightsopenAccess
dcterms.bibliographicCitation.volume2023, vol. 10
dcterms.bibliographicCitation.issueiss. 4
dcterms.bibliographicCitation.pagestart1
dcterms.bibliographicCitation.pageend12
dc.relation.doihttps://doi.org/10.3390/bioengineering10040438
dcterms.bibliographicCitation.journaltitleBioengineering
ulbbn.pubtypeZweitveröffentlichung
dc.versionpublishedVersion
ulbbn.sponsorship.oaUnifundOA-Förderung Universität Bonn


Dateien zu dieser Ressource

Thumbnail

Das Dokument erscheint in:

Zur Kurzanzeige

Die folgenden Nutzungsbestimmungen sind mit dieser Ressource verbunden:

Namensnennung 4.0 International