Show simple item record

A μ-biomimetic uncooled infrared psensor based on the infrared receptors of Melanophila acuminata

dc.contributor.advisorSchmieden, Hartmut
dc.contributor.authorSiebke, Georg
dc.date.accessioned2020-04-21T11:11:35Z
dc.date.available2020-04-21T11:11:35Z
dc.date.issued05.01.2016
dc.identifier.urihttps://hdl.handle.net/20.500.11811/6571
dc.description.abstractThe pyrophilous beetle Melanophila acuminata possesses an organ sensitive to IR radiation. It employs a photomechanic detection principle: A liquid filled pressure chamber is heated by absorbing the radiation. The liquid expands and leads to the deflection of a mechanosensitive dendrite. In addition, a sophisticated compensation mechanism prevents the build-up of large pressures.
In this work, a biomimetic IR sensor based on the IR receptors of Melanophila acuminata is developed by means of micro systems technology. The sensor consists of two liquid-filled chambers that are connected by a micro-fluidic system. Absorption of IR radiation by one of the chambers leads to the heating and expansion of a liquid. The increasing pressure deflects a membrane which is part of a plate capacitor with a diameter of 500 μm and an electrode distance of 500 nm. The micro-fluidic system and the second chamber represent a fluidic low-pass filter, preventing slow, but large pressure changes.
A theoretical model is developed which is able to predict the modulation frequency dependent response. It allows to calculate the filter properties of the compensation mechanism which is verified by an experimental test. A simplified sensor without the compensation mechanism is manufactured to analyse the influence of several parameters on the sensor’s sensitivity.
Finally, a solution for the fabrication of the μ-capacitor is presented. The large aspect ratio between electrode diameter and distance prevents to use a standard sacrificial layer process. The obtained capacitors pave the way to fabricate the complete full-featured sensor.
dc.language.isoeng
dc.rightsIn Copyright
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectMikrosystemtechnik
dc.subjectInfrarotsensor
dc.subjectungekühlt
dc.subjectBionik
dc.subjectKondensator
dc.subjectTiefpass
dc.subjectMikrofluidik
dc.subjectMEMS
dc.subjectinfrared sensor
dc.subjectuncooled
dc.subjectbiomimetics
dc.subjectcapacitor
dc.subjectlow-pass filter
dc.subjectmicro fluidics
dc.subject.ddc530 Physik
dc.subject.ddc620 Ingenieurwissenschaften und Maschinenbau
dc.titleA μ-biomimetic uncooled infrared psensor based on the infrared receptors of Melanophila acuminata
dc.typeDissertation oder Habilitation
dc.publisher.nameUniversitäts- und Landesbibliothek Bonn
dc.publisher.locationBonn
dc.rights.accessRightsopenAccess
dc.identifier.urnhttps://nbn-resolving.org/urn:nbn:de:hbz:5n-42040
ulbbn.pubtypeErstveröffentlichung
ulbbnediss.affiliation.nameRheinische Friedrich-Wilhelms-Universität Bonn
ulbbnediss.affiliation.locationBonn
ulbbnediss.thesis.levelDissertation
ulbbnediss.dissID4204
ulbbnediss.date.accepted03.11.2015
ulbbnediss.instituteMathematisch-Naturwissenschaftliche Fakultät : Fachgruppe Physik/Astronomie / Physikalisches Institut (PI)
ulbbnediss.fakultaetMathematisch-Naturwissenschaftliche Fakultät
dc.contributor.coRefereeKaupp, Ulrich Benjamin


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

The following license files are associated with this item:

InCopyright