Die dreidimensionale Echtzeit-Echokardiographie in der PädiatrieVergleich verschiedener Auswertungsprogramme und Erstellung volumetrischer Normwert-Perzentilen für den linken Ventrikel
Die dreidimensionale Echtzeit-Echokardiographie in der Pädiatrie
Vergleich verschiedener Auswertungsprogramme und Erstellung volumetrischer Normwert-Perzentilen für den linken Ventrikel
dc.contributor.advisor | Breuer, Johannes | |
dc.contributor.author | Krell, Kristina | |
dc.date.accessioned | 2020-04-25T18:38:36Z | |
dc.date.available | 2020-04-25T18:38:36Z | |
dc.date.issued | 13.11.2019 | |
dc.identifier.uri | https://hdl.handle.net/20.500.11811/7738 | |
dc.description.abstract | Einleitung: Die Dreidimensionale Echtzeit-Echokardiographie ist eine vielversprechende, nicht-invasive Methode zur Bestimmung linksventrikulärer Volumina und Funktion, wird jedoch aktuell in der Kinderkardiologie nicht routinemäßig angewandt, da unter anderem Referenzwerte für die pädiatrische Population fehlen. Ziel der Studie war es zum einen, den Einfluss verschiedener Bildanalyse-Software auf die Herzvolumina zu bestimmen sowie zum anderen, daraus abgeleitet, spezifische Normwerte für pädiatrische, linksventrikuläre Volumina zu erstellen. Methode: In einer prospektiv angelegten, multizentrischen Studie wurden bei 497 Kindern, im Alter von 0 bis 219 Monaten 3D-Echtzeit-Echokardiographische Untersuchungen des linken Ventrikels durchgeführt und die Bilder mit zwei gängigen Bildanalyse-Software ausgewertet (QLab 9.0 Philips und TomTec 4DLV2.7). Die Auswertung mit dem Programm vom Anbieter TomTec erfolgte anhand zweier unterschiedlicher Einstellungen, mit jeweils stärkerer oder geringerer automatischer Konturfindungsintensität. Die Erstellung der Normwertperzentilen erfolgte mit Hilfe der LMS Methode von Cole. Für 22 Probanden wurde ein Vergleich mit Ergebnissen der MRT angestellt. Ergebnisse: Eine Volumenanalyse mit beiden Programmen war für 370 der 497 Probanden (74,4%) möglich. Die Intra- und Interobservervariabilitäten zeigen eine gute Wiederholbarkeit und Bewerterunabhängigkeit (relativer bias für Enddiastolisches Volumen (EDV) ±SD in %: Intraobserver: QLab=-0.8±2.4; TomTec30=-0.7±7.2; TomTec75=-1.9±6.7; Interobserver: QLab=2.4±7.5; TomTec30=1.2±5.1; TomTec75=1.3±4.5). Für den Methodenvergleich zeigten sich deutliche Unterschiede sowohl zwischen den unterschiedlichen Auswertungsprogrammen als auch für Einstellungen in der Software selbst (bias: QLab vs. TomTec30: Endsystolisches Volumen (ESV)=0.8±23.6%; EDV=-2.2±17.0%). Besonders für kleine Ventrikelvolumina konnte in individuellen Fällen eine starke Abweichung der Ergebnisse beobachtet werden. Die geschlechtsspezifische Erstellung von Perzentilen erfolgte daher jeweils für die einzelnen Programme. Schlussfolgerung: Die dreidimensionale Echtzeit-Echokardiographie bietet die Möglichkeit der reproduzierbaren Erfassung des linksventrikulären Volumens und Funktion bei Kindern, ist jedoch abhängig von der gewählten Auswertungsmethode, sodass programmspezifische Perzentilen für die Bewertung der Messwerte notwendig sind. | |
dc.description.abstract | Real-Time Three-Dimensiona Echocardiography of the Left Ventricle—Pediatric Percentiles and Head-to-Head Comparison of Different Contour-Finding Algorithms : A Multicenter Study Background: Real-time 3D echocardiography (RT3DE) is a promising method for accurate assessment of left ventricular (LV) volumes and function, however pediatric reference values are scarce. The aim of the study was to establish pediatric percentiles in a large population and to compare the inherent influence of different evaluation software on the resulting measurements. Methods: In a multicenter prospective-design study, 497 healthy children (aged 1 day – 219 months) underwent RT3DE imaging of the LV (ie33, Philips). Volume analysis was performed using QLab 9.0 (Philips) and TomTec 4DLV2.7 (vendor-independent; testing high (TomTec75) and low (TomTec30) contour-finding activity). Reference percentiles were computed using Cole's LMS method. In 22 subjects, cardiac magnetic resonance imaging (CMR) was used as the reference. Results: 370/497 (74.4%) of the subjects provided adequate datasets. LV volumes had a significant association with age, body size and gender, therefore sex-specific percentiles were indexed to body surface area. Intra- and interobserver variability for both workstations were good (relative bias±SD for end-diastolic volume (EDV) in %: Intraobserver: QLab=-0.8±2.4; TomTec30=-0.7±7.2; TomTec75=-1.9±6.7; Interobserver: QLab=2.4±7.5; TomTec30=1.2±5.1; TomTec75=1.3±4.5). Intervendor agreement between QLab and TomTec30 showed larger bias and wider limits of agreement (bias: QLab vs. TomTec30: end-systolic volume (ESV)=0.8±23.6%; EDV=-2.2±17.0%) with notable individual differences in small children. QLab and TomTec underestimated CMR values with highest agreement between CMR and QLab. Conclusion: RT3DE allows reproducible noninvasive assessment of LV volumes and function. However, intertechnique variability is relevant. Therefore, our software-specific percentiles, based on a large pediatric population, serve as a reference for both commonly used quantification programs. | |
dc.language.iso | deu | |
dc.language.iso | eng | |
dc.rights | In Copyright | |
dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | |
dc.subject | 3D-Echtzeit-Echokardiographie | |
dc.subject | Perzentilen | |
dc.subject | Kinderkardiologie | |
dc.subject | linker Ventrikel | |
dc.subject | Volumetrie | |
dc.subject | 3D echocardiography | |
dc.subject | volumetry | |
dc.subject | left heart | |
dc.subject | nomogram | |
dc.subject | pediatric | |
dc.subject | children | |
dc.subject.ddc | 610 Medizin, Gesundheit | |
dc.title | Die dreidimensionale Echtzeit-Echokardiographie in der Pädiatrie | |
dc.title.alternative | Vergleich verschiedener Auswertungsprogramme und Erstellung volumetrischer Normwert-Perzentilen für den linken Ventrikel | |
dc.type | Dissertation oder Habilitation | |
dc.publisher.name | Universitäts- und Landesbibliothek Bonn | |
dc.publisher.location | Bonn | |
dc.rights.accessRights | openAccess | |
dc.identifier.urn | https://nbn-resolving.org/urn:nbn:de:hbz:5n-56095 | |
ulbbn.pubtype | Erstveröffentlichung | |
ulbbn.birthname | Wollens | |
ulbbnediss.affiliation.name | Rheinische Friedrich-Wilhelms-Universität Bonn | |
ulbbnediss.affiliation.location | Bonn | |
ulbbnediss.thesis.level | Dissertation | |
ulbbnediss.dissID | 5609 | |
ulbbnediss.date.accepted | 28.08.2019 | |
ulbbnediss.institute | Medizinische Fakultät / Kliniken : Kinderkardiologie | |
ulbbnediss.fakultaet | Medizinische Fakultät | |
dc.contributor.coReferee | Becher, Ulrich |
Files in this item
This item appears in the following Collection(s)
-
E-Dissertationen (1577)